MO-50000 system of water treatment, storage of water and water supply


Система водоподготовки, хранения воды и водоснабжения МО-50000. Фото 1Система водоподготовки, хранения воды и водоснабжения МО-50000. Фото 2
The MO-50000 system of water treatment, storage of water and water supply is designed for water purification of open reservoirs and wells from suspensions, colloids, disinfection from bacteria and viruses, including spore combat forms of biological agents, neutralization of highly toxic organic and inorganic substances, including combat toxic agents, deactivation of radioactive substances, removal of the compounds of iron, manganese, copper, sulfur, phosphorus, organic matters, including oil products, and dissolved salts, including the compounds of univalent, bivalent and polyvalent metals as well as for storage and delivery of the purified water under pressure to the consumer's main.

The system is designed for water purification in case of a pollution of the water intake with radioactive, toxic and bacteriological agents due to diversions, anthropogenic and natural disasters. The nominal throughput capacity of the system is 50 m3/h (1,200 m3/day), which is sufficient to provide:
  • 4,800 people according to the consumption rate established for urban people (250 l/person in day);
  • 15,000 people according to the consumption rate established for the military personnel of the APL-500 autonomous field camp (80 l/person in day);
  • 240,000 people when using water only for drinking and culinary.

The delivered system is fully ready for operation. It has the consumable, the set of instruments and the spare parts. The setup time is 6 h. The system consists of five 20-foot olive-green containers of 1C type connected between them by hydraulic and electrical communications:
  • Container N1 — the block for storage for source water;
  • Container N2 — the block of water treatment by ozone;
  • Container N3 — the block of mechanical filtration and preliminary sorption;
  • Container N4 — the block of microfiltration, final sorption and nanofiltration;
  • Container N5 — the block for storage and delivery of purified water.

Operability of the containers at extremely low and high temperatures is provided by the use of seamless fiber ceramics thermal insulation, between the blocks of which there are not convective cavities.

The covering of the containers is completely welded. The connections with gaps (bolted, riveted) are not used. The external surfaces of the containers are subjected to phosphatization before priming.

The system may be completed with the soft reservoirs of MR-NT series for drinking water of 100 м3 volume each used as the blocks for storage of source and purified water instead of the containers N 1 and N 5 as an option.

Technology of water purification


A source water comes to the container N1 where a water-supply is generated in case of cut-off of water delivery from the water intake. A source of the container N1 is pumped over to the container N2, where it is treated by ozone of high concentration (no less than 9 mass %) in two-zone counter-flow reactor. Ozone is produced in the high-voltage high-frequency generators of barrier discharge. A high concentration of ozone is achieved due to the use of the special technology of high-efficient cooling of the high-voltage electrodes (anodes) of the generators. Oxygen of a concentration no less than 95% produced in the oxygen concentrators being in the water treatment system is used as initial gas to obtain ozone. To increase a service time of the molecular sieves of the oxygen concentrators, an air coming to the concentrators is filtrated and dried.

The complete water disinfection from bacteria and viruses, including sporous forms of combat biological agents, oxidation of the compounds of polyvalent metals and semimetals (iron, manganese, copper, cobalt, mercury, bismuth, thallium, arsenic, antimony, etc.) for conversion into insoluble state as well as the complete or partial fracture of the organic compounds (including complex organophosphorous, chloroorganic and arsenic compounds) occur in the two-region counter-flow reactor. After processing by ozone in the reactor the organic compounds are turned to the harmless substances (H2O, CO2), or subjected to a partial destruction with the formation of less toxic and readily sorbate intermediate compounds.

Then a water comes to the container N3 for treatment, where the suspensions formed in water during oxidation in the container N2 are removed in the automatically flushing filters. A preliminary sorption of the products of a partial destruction of the organic compounds, formed during oxidation in the container N2, on activated carbons and a destruction of the residual dissolved ozone take place.

Then a water comes to the container N4 for treatment, where the water microfiltration with a removal of the residual hyperfine suspensions and the final sorption in the ANM material, which is capable to sorb the dissolved substances at a concentration inaccessible for a sorption on active carbons, take place.

The water fully purified from suspensions and dissolved organic compound comes to the nanofiltering membrane cases, where it is separated into the desalted permeate (purified water) and the super-salt concentrate by the membranes. The concentrate is wasted in sewerage.

To increase an interflushing service life of the nanofiltration membranes, a water is dosed with antiscalant before nanofiltration.

The purified water passes through the water counter, is provided with a dose of sodium hypochlorite and comes to the storage tank of the container N5.

The purified water under pressure from the container N5 is pumped in the consumer’s main. The design of the water distributing unit allows for the connection of the system to the available water supply systems with the high-lift pumps, the water delivery to the consumers without connection to mains (in tanks), the water supply of the consumers by temporary pipelines when using the system pumps for injection of the purified water.

Specifications
ParameterValue
Plan dimensions of the systemno more than 14000х7000 mm
Container dimensions of the systemno more than 6058 x 2438 x 2438 mm
Average treated water capacitynot less than 50.0 m3/h
Peak treated water flownot less than 60.0 m3/h
Purified water outlet pressurenot less than 0.2 MPa
Drain water pressure at system outlet0...0.6 MPa
Raw water pressure at system inletno more than 0.6 MPa
Drainage water flowno more than 25.0 m3/h
Lifetime before overhaul (treated water)not less than 500000 m3/h
Assigned lifetime (treated water)not less than 1000000 m3/h
Permissible loads on system containersup to 10 g with frequency up to 1 Hz
Power consumption of the systemno more than 74.0 kW
Dry weight of the systemno more than 30000 kg
Power supply380 V, 50 Hz

Parameters of water purification
IndicatorsUnit of measurementSource waterPurified waterDrinking water
Colordeg.30005
Odorpoints501
Tastepoints501
Kaolin turbiditymg/l60000.5
Iron totalmg/l200.10.3
Manganesemg/l1.00.050.05
Sulfidesmg/l300.003
Oxidabilitymg O2/l450.52
Ammoniummg/l100.030.05
Nitratemg/l2000.85
Chloridemg/l1500100150
Sulfatemg/l2800100150
Phosphatesmg/l100.53.5
Strontiummg/l4047
General hardnessmg-eq/l201.57
Total mineralizationmg/l60003001000

For water purification the system consumes an electrical energy up to 1.36 kW·h per 1 m3 of purified water.

Drainage waters of the system are nontoxic, and their water evacuation on a relief and in the natural reservoirs is admissible without additional treatment.

Control of the system can be carried out remotely.

The system is completely automated and does not demand a control from the user.

Sales contact information

Phone: +7 905 737-72-58
E-mail: market@niipolyus.ru

Building 1, 3 Vvedenskogo St., Moscow,
117342, Russian Federation